CDM-800 Gateway Router Revision 1
Rear Panel Connections MN-CDM800
3–13
3.3.3 48V Direct Current (DC) Power Interface (Optional)
Figure 3-8. CDM-800 DC Power Interface
3.3.3.1 DC Operation – Applying Power
Figure 3-9. Applying DC Power to the CDM-800
ToapplyDCpowertotheCDM‐800:
• First, connect the user‐supplied (+) and (–) DC power leads to their respective
terminals.Number18AWGminimumwiresarerecommended.
• Then,connecttheuser‐supplied DCpowerleadstothepowersource.
• Finally,swi
tchtheuni
tON.
Feature Description
1 On/OffSwitch
2 Screw‐inFuseHolders/Receptacles
3 PowerTerminalBlock
DCPowerSpecifications
InputPower
25W(typical)
245W(maximumwithBUC)
InputVoltage
48VDC,nominal
(36Vto60V)
ConnectorType TerminalBlock
FuseProtection
(2X)20mmSlow‐blowtypefuses:
T3A(3.0A)Main
T5A(5.0A)(BUC)