CDM-800 Gateway Router Revision 1
Rear Panel Connections MN-CDM800
3–8
3.2.4 Utility Connector Group
3.2.4.1 ‘TERM’ Connector
ThisRJ‐12femalemodularjackisunusedatthistime.
3.2.4.2 ‘FE’ (Fast Ethernet) Connector
• Thisinterfaceoperatesat10/100Mbps,halfandfullduplex,auto‐negotiating.
• ThemaximumEthernetpacketsizeis1522bytes(inclu dingEthernetheadersand
CRC)
3.2.4.3 ‘REDUNDANCY’ Connector
ConnectorType NameDirection
Type‘D’9‐pinfemale
REDUNDANCY In/Out
ThisinterfaceisusedforconnectiontoanoptionalCEFDCRS‐170A1:1Redundancy
SwitchforL‐Bandoper ation,ortheCRS‐1801:1RedundancySwitchfor70/140MHz
operation.
M:NdeviceredundancysupportisavailablewiththeseparatelypurchasedVipersat
ManagementSystem(VMS).
Table 3-1. REDUNDANCY Connector Pinout
ConnectorType Name Direction
RJ‐45femalemodularjack
FE
In/Out
PIN# DESCRIPTION DIRECTION
1 GROUND –
6 TRANSMITSERIALDATA–AUXILIARYCHANNEL OUT
2 RECEIVESERIALDATA–AUXILIARYCHANNEL IN
7 REDUNDANCYOUT1 OUT
3 REDUNDANCYIN1 IN
8 REDUNDANCYOUT2 OUT
4 REDUNDANCYIN2 IN
9 FUSED+12VOLT OUT
5 REDUN_TX_EN OUT
Kommentare zu diesen Handbüchern