CSAT-5060/XSAT-7080 Transceiver iPAQ Link Revision 2
Operations MN/CiLink.IOM
3–6
3.3.2.2 Main Menu Æ Configuration Æ Signal Path
The currently selected transceiver is the unit that will be polled for status
information in the
Signal Path configuration XCVR# selection box:
XCVR1 is the default selection and XCVR2 is not selectable if CiLink is set to operate under
standalone (non-redundant) system parameters (see
Configuration Æ System Type for detailed
information).
The status-only ONLINE/OFFLINE field to the right of the XCVR# selection box indicates the
active line status of the currently selected transceiver.
The Up Converter and Down Converter sections allow the user to view and/or change the
following transceiver parameters:
TX status-only – This is a summary of the Amp=On,
Mute=Off and no faults present (Up Converter section)
RX status-only This is a summary of the Mute=Off and no
faults present (Down Converter section)
Amp [On/Off] – The user can change the state of the
amplifiers in the currently selected transceiver to
On or Off.
Mute [On/Off] The user can mute the output of the
currently selected transceiver when set to
On.
Attenuation Both transmit and receive attenuation are
user-configurable. The TX attenuation can be selected
between 00.00 dB and 25.00 dB in 0.25 dB increments; the
RX attenuation can be selected between 00.00 dB and 20.00
dB in 0.25 dB increments.
Frequency – Both transmitter and receiver frequencies are user-configurable. The TX or
RX frequency can be selected to any frequency divisible by either 1.0 MHz or 2.5 MHz in
the valid TX or RX frequency range.
IMPORTANT
The Up and Down Converter Frequency and Attenuation settings can only be
chan
g
ed if the currentl
y
selected XCVR is ONLINE. Use the Windows Ke
y
pad
to manually enter new values for these settings in the provided data fields.
Tap
[Set Data] to save the updated configuration selections. Otherwise, tap [ok] to return to the
Main Menu from the Configuration Æ Signal Path screen without saving any changes.