LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter MN-LPOD
System Connections, Installation and Startup Revision 10
2–4
PS 1/PS 1.5 PS 2
2.3 Interface Connectors
2.3.1 Connector ‘J1 | LBAND IN or ‘J1 | Tx IN’
The RF input connector is a Type N’ female connector.
Labeled J1 | LBAND IN on the LPOD PS 1 and PS 1.5 models
or ‘J1 | Tx IN on the LPOD PS 2 unit, typical input levels (-30
dBm) depend on desired output power and unit attenuation.
To prevent damage to the LPOD, RF input levels should not
exceed +15 dBm.
2.3.2 Connector ‘J2 | RF OUT
WARNING! FOR SAFETY REASONS, NEVER LOOK DIRECTLY INTO THE WAVEGUIDE
OUTPUT.
TheJ2 | RF OUT connector may be a waveguide or coaxial interfacethe type of interface
used depends on the LPOD model and/or frequency range of the unit, as described in Table 2-1
and as shown in Figure 2-3, Figure 2-4, and Figure 2-5.
Table 2-1. J2 | RF OUT’ Interface Type
Unit
Frequency Band
Output Type
FIGURE
PS 1
C
Type ‘N’ Female (Standarsd)
CPR137G (Optional)
2-1
X CPR112G (Waveguide)
Ku WR75G (Waveguide)
PS 1.5
C CPR137G (Waveguide)
2-2 X CPR112G (Waveguide)
Ku WR75G (Waveguide)
PS 2
C CPR137G (Waveguide)
2-3
X
CPR112G (Waveguide)
Ku
WR75G (Waveguide)