LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–32
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Rate
Sets or returns the remote baud rate in the form xxxx, where:
2400 = 2400 baud
4800 = 4800 baud
9600 = 9600 baud (default value)
19K2 = 19200 baud
38K4 = 38400 baud
Note: When changing baud rates remotely the response to the command will be returned using the same baud
rate as that used to send the command.
Examples: <1/SBR=9600’cr’
>0001/SBR=9600’cr’’lf’
<1/SBR?’cr’
>0001/SBR=09600’cr’’lf’
SBR?
SBR*
(See Description of
Arguments)
numeric
Sets or returns switching of the bias tee into the through state or into the off state, in the form x, where:
0 = Off State (mute LNB) (default value)
1 = Through State (unmute LNB)
Notes:
1) The bias tee provides a means of muting the LNB. The SBT state will be controlled by the amplifier mute
state while running in redundant mode, but while the unit is not in redundant mode the bias tee may be set
independently of the amplifier mute state.
2) To send this command the unit must have the bias tee option installed otherwise a mode error will result. A
mode error will also result if this command is sent while the unit is running in redundant mode.
SBT?
SBT*
(See Description of
Arguments)
numeric
Sets or returns the FSK Address in the form xx, where:
xx=01-15
Default value: 01
Example: <1/SFA=01’cr’
>0001/SFA=’cr’’lf’
SFA?
SFA*
(See Description of
Arguments)
Status
E
Returns the condition of the summary fault relay in the form x, where:
0 = Not Faulted (SumFLT_COM J6 pin K is not connected to SumFLT_NC J6 pin M)
1 = Faulted (SumFLT_COM J6 pin K is connected to SumFLT_NC J6 pin M)
Example: <1/SFS?
(See Description of
Arguments)