LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Introduction Revision 10
1–10
1.5.3 Optional LNB Bias / Reference
LNB Bias Voltage
Software selectable tone on/off, 12/18V, 450 mA max
LNB 10 MHz Reference Output Level
0 dBm ±5 dB
LNB Input / Output Return Loss
15 dB
LNB Input / Output Gain
10 dB ± 2 dB (950-1750 MHz)
-1 dB ± 2 dB (optional)
LNB Input / Output Gain Flatness
± 1 dB (950-1750 MHz)
LNB input / Output Isolation (Mute condition)
55 dB min
1.5.4 Environmental
Temperature
Operating
-40º to 122ºF (-40º to 55ºC)
-40º to 140ºF (-40º to 60ºC)
-67º to 167ºF (-55º to 75ºC)
100% condensing rain 2” per hour
Normal commercial shipping and handling
1.5.5 Physical
Weight
47 lbs (21.32 kg) Nominal
Dimensions
(excluding connectors)
See Sect. 1.6 for all
dimensional envelope
figures
PS 1
12.65 x 6.26 x 7.37 in.
(321.3 x 159 x 187.2 mm)
PS 1.5
12.78 x 6.14 x 7.05 in.
PS 2
16.18 x 8.80 x 9.78 x in.
(427 x 223.5 x 248.4 mm)
Connectors
RF Output
PS 1
C-Band / X-band: Type ‘N’ Female (standard), CPR137G
(optional)
PS 1.5
X-Band: CPR112G
PS 2
C-Band: CPR137G
X-Band: CPR112G
M&C/Ethernet/
Redundancy Switches
19-pin MS style (single integrated cable assembly available,
dependent upon configuration)