LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–27
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Performs a soft reboot in the form x, where:
1 = Reboot System
RBT?
RBT*
(See Description of
Arguments)
Configuration
Status
Returns the configuration status of the unit.
Examples:
RCS=’cr’
ATT=12.75’cr’
AMP=1’cr’
MUT=1’cr’
ONL=1’cr’
ESW=1’cr’
AOF=00.00’cr’
AFR=1’cr’
XRF=N/A’cr’’lf’ (see Note)
Where:
ATT= attenuation in dB
AMP= RF power amplifier state, 0=OFF, 1=ON
MUT=RF mute state, 0=un-muted, 1=muted
RED=Online status for redundancy
ESW=Redundancy state and mode,
states: 0=OFF, 1=ON Tx only, 2=ON Tx & Rx
AOF=Attenuator Offset in dB
AFR= auto fault recovery, 0=manual, 1=auto
XRF = External reference status, N/A = no external reference, 05M for 5 MHz, and 10M for a 10 MHz
Note: XRF will always be N/A if the internal reference oscillator option is not installed.
(See Description of
Arguments)
Sets or returns Redundancy Online status in the form x, where:
0 = Offline
1 = Online
Note: this command is functionally identical to the ONL command.
Example: <1/RED=1’cr’
RED?
RED*