5.2.5.2 Alarm Settings
See Figure 10 – Alarm Settings. Use Alarm Settings to define these parameters:
• Alarm level the SLA must violate
• Delay before the SLA indicates it has been violated
• Minimum outage threshold for the SLA to trigger
• Filter which alarms trigger SLA impact
Figure 10 – Alarm Settings
Violation Level – sets the Alarm Level at which the SLA must start to indicate violations
Delay Time – sets a delay period in seconds; after this delay, the SLA starts to indicate violations (e.g., for
backup delays)
Minimum Outage Threshold – sets the minimum outage period before the SLA starts to indicate violations
Note: The duration of an alarm includes any delay time in effect. It does not include any minimum outage
threshold in effect.
Violation Settings – set alarm filters or set significance weights for specific alarms.