UT-4500-A Series Upconverters Revision 1
Appendix A MN-UT4500A
A–17
A.7.2.7 Auto Fault Recovery
The converter output is muterd automatically in the event of a detected fault. Auto Fault
Recovery, if enabled, will cause the output signal to go active (unmuted) if all faults clear. If
disabled, the output will remain muted even after all faults clear until a MUT_OFF command is
received. If Auto Fault Recovery is enabled and the converter detects the same fault more than
five times in a five minute interval (ex: multiple IFLO lock detect faults) the function reverts to
DISABLED and the converter remains muted. The default is ON.
Command
Details
Set Fault Recovery:
<DEV/AFR_xxx'cr' xxx = ON or 0FF
Confirmation:
>DEV/AFR_xxx'cr''lf']
Retrieve Status:
<DEV/AFR_'cr'
Confirmation:
>DEV/AFR_xxx'cr''lf']
A.7.2.8 Program Preset
Use the PGM command to store up to 32 preset frequency and attenuation settings.
Command
Details
Program Preset:
<DEV/PGM_nn_xxxxx.xxx_yy.yy'cr'
Confirmation:
>DEV/PGM_nn_xxxxx.xxx_yy.yy'cr''lf']
Note: nn = Preset Number = 01 to 32.
xxxx.xxx = Frequency = RFLow to RFHigh (for example, 14000.000 to 14500.000 MHZ for Model
UT-4514).
yy.yy = Attenuator = 00.00 to 25.00.
A.7.2.9 Display All Presets
Use the DPS command to display all of the programmed preset values.
Command
Details
Display Presets:
<DEV/DPS_'cr'
Confirmation:
>DEV/DPS_'cr'
P01 xxxxx.xxx yy.yy'cr'
to
P32 xxxxx.xxx yy.yy'cr''lf']
Where: xxxxx.xxx = Frequency
yy.yy= Attenuator
Note: Only programmed preset numbers are returned. If no preset(s) is programmed, “No Pre-
Selects Programmed” is returned.