MBT-4000 Multi-Band Transceiver System Revision 4
Remote Control MN/MBT4000.IOM
A–20
Parameter
Type
Command
(Instruction
Code and
qualifier)
alid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Maintenance
Status
N/A All MBT-4000 -
103 bytes,
alphanumeric
BDC –
98 bytes,
alphanumeric
BUC –
98 bytes,
alphanumeric
Query only.
Used to Query the maintenance status of the unit.
Example for MBT-4000 base:
<0001/RMS?{cr}
>0001/RMS={cr}{lf}
15VT1=015.1{cr}
7V5T1=007.7{cr}
5VLT1=005.0{cr}
28VT1=027.2{cr}
REFVT=001.3{cr}
LNA_1=000.0{cr}
LNA_2=000.0{cr}
RFSWP=B{cr}
IFSWP=N{cr}
RRFSW=B{cr}
RIFSW=B{cr}{lf}
Example for BUC:
<0001A2/RMS={cr}
>0001A2/RMS={cr}{lf}
15VT=015.1{cr}
7V5T=007.6{cr}
5VLT=005.2{cr}
REFV=XXX.X{cr} (reserved for future use)
SYNT=007.2{cr}
POUT=XXX.X{cr} (reserved for future use)
TEMP=+25.0{cr}{lf}
Example for BDC:
<0001A1/RMS={cr}
>0001A1/RMS={cr}{lf}
15VT=015.1{cr}
7V5T=007.6{cr}
5VLT=005.2{cr}
REFV=XXX.X{cr} (reserved for future use)
SYNT=007.2{cr}
LNAC=255.0{cr}
TEMP=+25.0{cr}{lf}
Note: “REFV” will show tuning voltage of reference OSC for
standalone. Otherwise REFV=xxx.x which means Not
Applicable.
N/A RMS?
RMS=x….x
(see description
for details of
arguments)