Ku-Band Satellite Transceiver Revision 9
FSK Remote Control Commands MN/KST2000AB.IOM
E-23
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(note that all arguments are ASCII numeric codes, that is, ASCII
codes between 48 and 57)
Response to Command (target to
controller)
Query
(Instruction
Code and
qualifier)
LNA Stored
Faults
n.a. 1 byte Query only.
<add/LSF?X’cr’
>add/LSF=A’cr’’lf’ or
>add/LSF=NO_FAULT’cr’’lf’
Where: A=LNA Status, 0=OK, 1=FLT
X= Stored Fault Locations (0 to 9)
LSF= (message ok)
LSF? (received ok, but invalid arguments
found)
LSF* (message ok, but not permitted in
current mode)
LSF?
AGC Stored
Faults
n.a. 3 bytes Query only.
<add/ASF?X’cr’
>add/ASF=ABC’cr’’lf’ or
>add/ASF=NO_FAULT’cr’’lf’
Where: A=Loop Convergence, 0=OK, 1=FLT
B=Excessive Input Power (EIP), 0=OK, 1=FLT
C=Insufficient Input Power (IIP), 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)
ASF= (message ok)
ASF? (received ok, but invalid arguments
found)
ASF* (message ok, but not permitted in
current mode)
ASF?
Common
Equipment
Stored Faults
n.a. 4 bytes Query only.
<add/CSF?X’cr’
>add/CSF=ABCD’cr’’lf’ or
>add/CSF=NO_FAULT’cr’’lf’
Where: A=–7V PS Status, 0=OK, 1=FLT
B=+7V PS Status, 0=OK, 1=FLT
C=+12V PS Status, 0=OK, 1=FLT
D=+17V PS Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)
CSF= (message ok)
CSF? (received ok, but invalid arguments
found)
CSF* (message ok, but not permitted in
current mode)
CSF?
Clear Stored
Faults
CSA= None Command only.
<add/CSA=’cr’
>add/CSA=’cr’’lf’
CSA= (message ok)
CSA? (received ok, but invalid arguments
found)
CSA* (message ok, but not permitted in
current mode)
n.a.