MCED-100 MetaCarrier Embedding Device Revision 1
Introduction MN-MCED100
1–9
1.4 MCED-100 Specifications
1.4.1 Product Feature Specifications
Specification Description
Dimensional Envelope 19.0 W x 16.2 D x 1 RU (1.7) H inches (483 W x 411 D x 44 H mm)
Weight 5.75 lbs (2.6 kg)
Temperature
Operating 32° to 122°F (0° to 50°C)
Storage -4° to 158°F (–20° to 70°C)
Humidity
Operating
95% maximum, non-condensing
Storage 99% maximum, non-condensing
Vibration Per MIL-STD-810F Method 514.5 Category 4a
Front Panel
7 Light-Emitting Diodes (LEDs):
UNIT STATUS (Green/Amber/Red)
STORED EVENT (Amber)
ONLINE (Green)
TEST MODE (Red)
CARRIER DETECT (Green/Amber/Red)
CARRIER ID (Green)
GPS ACTIVE (Green/Red)
Rear Panel
Connectors
Data Interfaces
1X RJ-45 10/100 BaseT Fast Ethernet
1X DB-9M EIA-232 interface for basic serial configuration
GPS Support
1X DB-9M EIA-232 serial input for receiving GPS information from an optional external GPS
device.
1X Type SMA female connector for 50 RF interface with an external GPS antenna (for use
with internal GPS).
L-Band
50 Type ‘N’ female input/output:
DC Power Pass
FSK Pass
Reference Pass
70/140 MHz 75 Type BNC female input/output
AC Power Supply Rear Panel-installed Module includes On/Off Switch
AC Operating Voltage
100V – 240V AC, +6%/-10% autosensing
(Total absolute maximum range is 90V – 254V AC)
Power Consumption 30W typical
Fuse Protection 2X 120/240VAC T2A 5x20mm slow-blow fuses
Frequency 50-180 MHz or 950-1250 MHz (±1.0ppm) in 100 Hz steps
Impedance
L-Band 50
70/140 MHz 75
Return Loss
L-Band Minimum 13dB
70/140 MHz Minimum 15dB
Insertion Loss
L-Band Maximum 3dB
70/140 MHz Maximum 2dB