MBT-4000 Multi-Band Transceiver System Revision 4
Remote Control MN/MBT4000.IOM
A–7
Parameter
Type
Command
(Instruction
Code and
qualifier)
V
alid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Automatic
Fault
Recovery
State
AFR=x All
1 byte, value
of 0, 1
Command or Query.
Enable Automatic Fault Recovery on a BXC, where:
0=Disabled
1=Enabled
Example: AFR=1
AFR=(message OK)
AFR? (received OK,
but invalid arguments
found)
AFR*(message OK,
but not permitted in
current mode)
AFR? AFR=x
(same format as
command
arguments)
Attenuation ATT=xx.xx BDC
BUC
5 bytes,
numeric
Command or Query.
Valid attenuation level, in dB, at 0.25dB step size as factory
default.
Example: ATT=08.25
ATT=(message OK)
ATT? (received OK,
but invalid arguments
found)
ATT*(message OK,
but not permitted in
current mode)
ATT! (Command not
accepted by MBT-
4000 base unit. It
must be addressed
to BUC or BDC sub-
units)
Clear All
Stored Alarms
CAA= All None Command only.
Instructs the slave to clear all Stored Events.
This command takes no arguments.
CAA=(message OK) N/A N/A
Concise AUX
COMM I/O
N/A MBT n=Slot
1=AUX
COMM 1
2=AUX
COMM 2
Query only.
Used to Query the Concise AUX COMM I/O of the MBT-4000
base unit, where: n=1 (AUX COMM 1) or 2 (AUX COMM 2)
Example: <0001/CAI?n{cr}
>0001?CAI=nabcd{cr}{lf}
Where:
n=1 or 2 (AUX COMM)
a=12V (0=Off, 1=On)
b=IOA (O=logic low [voltage input < 0.5],
1=logic high [voltage input > 2.7 vdc)
c=IOB (O=logic low [voltage input < 0.5],
1=logic high [voltage input >2.7 vdc]
d=Reserved (Always zero)
CAI=(message OK)
CAI? (received OK,
but invalid arguments
found)
CAI*(message OK,
but not permitted in
current mode)
CAI?n CAI=nabcd
(see description
for details of
arguments)