DMD2050E Universal Satellite Modem User Interfaces
MN-DMD2050E Revision 2 4–16
{-30 to –90} Sets the minimum carrier receive level when a carrier drops
below this level. The modem will sweep and try to acquire a
new signal. This prevents extremely small carriers from falsely
locking the modem.
{0.0 – 9.9 dB} Select an EB/NO level that will trigger an alarm when the
received EB/NO is worse.
4.4.2.4 DATA (menu)
Refer to Technical Specs Set the Data Rate in bps steps via the
Front Panel Arrows or Keypad.
View the Symbol Rate.
Viterbi {1/2, 3/4, 7/8, None}
Optional FEC Rates:
Sequential {1/2, 3/4, 7/8}
CSC {3/4}
Trellis (8PSK) {2/3}
TPC (BPSK) {5/16, 21/44} ≤ 20Mbps
TPC (OQPSK/QPSK) {1/2, 3/4, 7/8} ≤ 20Mbps
TPC (8PSK/8QAM) {3/4, 7/8}
TPC (16QAM) {3/4, 7/8}
DVB VIT {2/3, 5/6}
DVB Trellis {3/4, 5/6, 7/8, 8/9}
LDPC (B/O/QPSK) {1/2, 2/3, 3/4}
LDPC (8PSK/8QAM) {2/3, 3/4}
LDPC (16QAM) {3/4}
EBEM (B/QPSK) {1/2, 2/3, 3/4, 7/8, 19/20, None}
EBEM (8PSK) {1/2, 2/3, 3/4, 7/8, 19/20, None}
EBEM (16APSK) {1/2, 2/3, 3/4, 7/8, 19/20, None}
Select the Rx Code Rate and Type.
{DISABLE, ENABLE} Disable or enable the IFEC Interleaver.
{ENABLED, DISABLE} Enable or disable the Differential Decoder.
Having the decoder enabled ensures
proper phase lock. May not be adjustable
in some modes.