SDM-650B Satellite Modem Remote Control Operation
Rev. 6 B–37
B.2.3.4 Set Modulator Output Power Level
Command: <add/MOP_snn.n”cr”
Response: >add/MOP_snn.n”cr””lf”]
Status Only: <add/MOP_”cr”
Response: >add/MOP_snn.n”cr””lf”]
Where:
snn.n = +20.0 to -45.0, in 0.5 dB increments for 140 MHz modulator.
snn.n = +20.0 to -30.0, in 0.5 dB increments for 70 MHz modulator.
Notes:
1. Must be within 25.0 dB of the modulator power offset value (see MPO_) for the
140 MHz modulator, and within 10.0 dB of the modulator power offset for the
70 MHz modulator.
2. When local AUPC enable is programmed ON, the (MOP) Modulator Output
Power command is not allowed; only MOP status is allowed. See “LPC_”
command.