UT4500 Series Up Converter MN/UT4500.IOM
Remote Control Revision 2
75
5.6.4.10 PACKED ALARM STATUS
Packed Alarm Status: <DEV/PACRAS_'cr'
Confirmation: >DEV/PACRAS_abcdefghijk'cr''lf']
where:
a = 1 if V15 Fault, else 0
b = 1 if V14 Fault, else 0
c = 1 if VCC Fault, else 0
d = 1 if V5D Fault, else 0
e = 1 if TEMP Fault, else 0
f = 1 if IFLO Fault, else 0
g = 1 if SUM Fault, else 0
h = 1 if COARSE Fault, else 0
I = 1 if FINE Fault, else 0
j = 1 if HSB Fault, else 0
k = 1 if EXT REF Fault, else 0
5.6.5 STORED ALARM
The 100 alarms are date/time stamped and stored in memory as they occur. The alarm
entry is also updated with its date/time of clearance. The entry remains in memory until
it is removed by command.
5.6.5.1 TOTAL STORED ALARMS
This command retrieves the total number of stored alarms and the time and date of the
most recent alarm.
Retrieve Total Alarms: <DEV/TSA_'cr'
Confirmation: >DEV/TSA_TOTAL:nn'cr'
LAST:hh:mm:ss mm/dd/yy'cr''lf']
where:
nn = 0 to 99; the 100
th
alarm will be ER
hh.mm.ss = time in hour:minute:second
mm/dd/yy = date in month/day/year
5.6.5.2 CLEAR ALL STORED ALARMS
Clear Alarms: <DEV/CAA_YES'cr'
Confirmation: >DEV/CAA_CLEARED'cr''lf']