Part Number MN/CRS100.IOM Revision 2 CRS-100 1:1 Redundancy Switch Operation Manual (Accessory Product for use only with Comtech
CRS-100 1:1 Redundancy Switch Revision 2 Preface MN/CRS100.IOM v About this Manual This manual provides installation and operation information for
CRS-100 1:1 Redundancy Switch Revision 2 Preface MN/CRS100.IOM vi IMPORTANT INFORMATION – PLEASE READ BEFORE INSTALLATION AND USE Safety Notices
CRS-100 1:1 Redundancy Switch Revision 2 Preface MN/CRS100.IOM vii Operation in vehicles or other transportable installations which are equipped to
CRS-100 1:1 Redundancy Switch Revision 2 Preface MN/CRS100.IOM viii
CRS-100 1:1 Redundancy Switch Revision 2 Preface MN/CRS100.IOM ix Warranty Policy This Comtech EF Data product is warranted against defects in mat
MN/CRS100.IOM 1–1 Chapter 1. INTRODUCTION The CRS-100 1:1 Redundancy Switch (Figure 1-1) is a companion product for use with Comtech EF Data CDM-500
CRS-100 1:1 Redundancy Switch Revision 2 Introduction MN/CRS100.IOM 1–2 MN/CRS100.IOM Accordingly, a 1:1 system comprises an Online Modem, a Standb
2–1 Chapter 2. INSTALLATION 2.1 Unpacking Inspect shipping containers for damage. If shipping containers are damaged, they should be kept until th
CRS-100 1:1 Redundancy Switch Revision 2 Introduction MN/CRS100.IOM 2–2 2.3 Configuration There are only two configuration switches to set, which
CRS-100 1:1 Redundancy Switch Revision 2 Introduction MN/CRS100.IOM 2–3 Figure 2-1. Cabling Details
CRS-100 1:1 Redundancy Switch Revision 2 Introduction MN/CRS100.IOM 2–4 The following cable assemblies are supplied with the CRS-100 as shown in
CRS-100 1:1 Redundancy Switch Revision 2 Introduction MN/CRS100.IOM 2–5 2.5 CRS-100/CIC-50 Cabling Details Figure 2-2 shows how to connect the C
CRS-100 1:1 Redundancy Switch Revision 2 Introduction MN/CRS100.IOM 2–6 Figure 2-2. CRS-100/CIC-50 Cabling Details 25 PIN D MALE25 PIN D MALECO
MN/CRS100.IOM 3–1 Chapter 3. PHYSICAL DESCRIPTION The CRS-100 is constructed as a free-standing module measuring 1.7H x 5.7W x 4.1D inches (4.3H x 14
CRS-100 1:1 Redundancy Switch 3–2 MN/CRS100.IOM 3.3 Side Panel - Right Side On the side panel (Figure 3-1) to the right are the two Tx IF ports, ‘A
CRS-100 1:1 Redundancy Switch Revision 2 \Physical Description MN/CRS100.IOM MN/CRS100.IOM 3–3 3.4 Side Panel - Left Side On the side panel (F
CRS-100 1:1 Redundancy Switch 3–4 MN/CRS100.IOM This page has been intentionally left blank.
Rev. 1.2 4–1 Chapter 4. FUNCTIONAL DESCRIPTION The CRS-100 connects to two modems, an Online unit, and a Standby unit, monitors the fault status
Functional Description CRS-100 1:1 Redundancy Switch 4–2 Rev. 1.2 hence lose approximately 3.5 dB in output power level) the CRS-100 does not intro
Rev. 1.2 5–1 Chapter 5. CONNECTOR PINOUTS Table 5-1. Data Connector - 25 Pin ‘D’ Type Female Pin Generic Signal description Direction EIA-422
Filename: T_ERRATA 1 Errata A Comtech EFData Documentation Update Subject: Change Part No. for AUX Cable Date: January 6, 2006 Document: CRS-100
Connector Pinouts CRS-100 1:1 Redundancy Switch 5–2 Rev. 1.2 IMPORTANT For correct operation of the CRS-100, the Modems must have the following Fi
MN/CRS100.IOM 6–1 Chapter 6. OPERATION 6.1 AUTOMATIC OPERATION Having connected the cables in accordance with the instructions and diagram in Secti
CRS-100 1:1 Redundancy Switch Revision 2 Operation MN/CRS100.IOM 6–2 MN/CRS100.IOM 6.1.2 (INFO) MISC (Miscellaneous information) MISC: IF-LOOP
CRS-100 1:1 Redundancy Switch Revision 2 Operation MN/CRS100.IOM MN/CRS100.IOM 6–3 6.1.3 (CONFIG) MASK (Alarm mask) ALARM MASK: AGC Eb/No RX
CRS-100 1:1 Redundancy Switch Revision 2 Operation MN/CRS100.IOM 6–4 MN/CRS100.IOM 6.2 Manual Operation There are two ways to force a manual switc
MN-CRS100.IOM 7–1 Chapter 7. SUMMARY OF SPECIFICATIONS Equipment Type 1:1 Redundancy Switch Modems Supported CDM-500, CDM-550 and CDM-550T Digital S
CRS-100 1:1 Redundancy Switch Revision 2 Summary Of Specifications MN-CRS100.IOM 7–2 MN-CRS100.IOM IF Frequency range 52 - 176 MHZ (works with both
METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX
Filename: T_ERRATA 2 COMTECH PART NO.PL/WR9320-1 Figure 2-1. Cabling Details
Filename: T_ERRATA 1 Errata B Comtech EFData Documentation Update Subject: Change Part No. for AUX Cable Date: January 6, 2006 Document: CRS-100
Copyright © Comtech EF Data, 2000. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, (480) 33
ii Customer Support Contact the Comtech EF Data Customer Support Department for: • Product support or training • Information on upgrading or retur
iii Table of Contents CHAPTER 1. INTRODUCTION...... 1–1 CHAPTER 2. INST
CRS-100 1:1 Redundancy Switch Revision 2 Preface MN/CRS100.IOM iv CHAPTER 6. OPERATION ...............