MN-DMD1050 Revision 9 Comtech EF Data is an AS9100 Rev B / ISO9001:2000 Registered Company DMD1050 Satellite Modem Board Installatio
Table of Contents Revision 9 DMD1050 Satellite Modem Board MN-DMD1050 iv 3.3.5 Connecting the Terminal ...
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–6 Revision 9 7.3.1.1 Login Screen Upon initially accessing the Password Setup, IP Administ
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–7 Revision 9 7.3.2 Password Setup The Access Menu allows for multiple operators to be allow
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–8 Revision 9 Preferences Menu Figure 7-5. Modem Preferences menu User Confirmation:
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–9 Revision 9 7.3.3 IP and Application Administration The Modem Addressing menu provide
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–10 Revision 9 IP TEST: The IP Test boot mode has a similar behavior to the default boot m
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–11 Revision 9 Configuring Applications Figure 7-7. Configuring Applications SNMP Setup:
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–12 Revision 9 Table 7-5. SNMP Parameters SNMP VERSION: V1 & V2 TRAP VERSION: V1
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–13 Revision 9 Configuring the PC Figure 7-8. Configuring the PC
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–14 Revision 9 7.3.4 Monitor and Control Menu Under this menu, all modem functions that are
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–15 Revision 9 MIL-STD 188-165A: (MILSTD-188-165A) For Data Rates: 9.6 K – 20.0
Table of Contents Revision 9 DMD1050 Satellite Modem Board MN-DMD1050 v CHAPTER 4. REAR PANEL INTERFACE ...
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–16 Revision 9 Modulation: {QPSK, BPSK, OQPSK, 8PSK, 16QAM} Allows the user to select the
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–17 Revision 9 Differential Coding: {ENABLED, DISABLE} Allows the user to enable or dis
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–18 Revision 9 Transmit / Reed-Solomon Menu These selections are active only when the Reed-S
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–19 Revision 9 Transmit / AUPC Menu Figure 7-12. Transmit / AUPC Menu LOCAL AUPC (menu)
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–20 Revision 9 EFDATA AUPC: When configured for EFDATA AUPC the minimum Transmit Power is
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–21 Revision 9 TRACKING RATE {0.5 to 6.0} Allows the user to set the rate at which the c
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–22 Revision 9 7.3.4.2 Receive Menu The Receive menu contains sub menus; General | IF, Dat
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–23 Revision 9 MIL\188-165A: (MILSTD-188-165A) For Data Rates: 9.6 K – 20.0 Mbps
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–24 Revision 9 Sweep Delay (sec): {0.0 – 900.0 sec} Allows the user to set the reacq
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–25 Revision 9 Receive / Data Menu Figure 7-14. Receive / Data Menu Data Rate (bps
Table of Contents Revision 9 DMD1050 Satellite Modem Board MN-DMD1050 vi 6.10 DMD1050 BER Specifications ...
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–26 Revision 9 Scrambler Selection {NONE, V.35-IESS, V.35 CITT, V.35 EF, IBS w/Optional Fr
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–27 Revision 9 Receive / Reed-Solomon Menu Figure 7-15. Receive / Reed-Solomon Menu
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–28 Revision 9 7.3.4.3 Interface Menu Interface / TX Setup Menu Figure 7-16. Interfac
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–29 Revision 9 SCT Clock Source: {INTERNAL (SCT), SCR (Rx SAT CLK)} Select SCT Source to
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–30 Revision 9 Interface / RX Setup Menu Figure 7-17. Interface / RX Setup Menu Circuit
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–31 Revision 9 BUFFER CLOCK SOURCES {SCTE (External), SCT (Internal), Rx Sat} Priority
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–32 Revision 9 Interface / General Menu Figure 7-18. Interface / General Menu Ext
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–33 Revision 9 7.3.4.4 Monitor Menu Monitor | Voltages Menu Figure 7-19. Monitor | Vol
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–34 Revision 9 Rx Buffer Level (Fill %): {0 – 100%} Displays the status of the Doppl
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–35 Revision 9 Monitor / Eth Link Status Menu Figure 7-20. Monitor / ETH Link Status Menu
Table of Contents Revision 9 DMD1050 Satellite Modem Board MN-DMD1050 vii APPENDIX C. TCP/IP ETHERNET SETUP ...
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–36 Revision 9 PORT 2 STATUS {See the note above} Displays the current status of LAN
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–37 Revision 9 7.3.4.5 Alarms Menu Alarms / Transmit Menu Figure 7-22. Alarms /Transmit
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–38 Revision 9 Ethernet WAN {Pass/Fail, Unmasked/Masked} Indicates that the interfac
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–39 Revision 9 Alarms / Receive Menu Figure 7-23. Alarms / Receive Menu MAJOR ALARMS
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–40 Revision 9 solid indication points toward a configuration problem within the modem. Et
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–41 Revision 9 RESET LATCHED ALARMS Clicking on this button will reset (Clear) all Latc
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–42 Revision 9 +3.3V Supply {Pass/Fail, Unmasked/Masked} Displays the measured voltag
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–43 Revision 9 IDR Backwards #2 SAT Alarm: {Pass/Fail, Unmasked/Masked} IDR Backw
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–44 Revision 9 7.3.4.5.1 System Menu System / Terminal / Remote Menu Figure 7-26. System
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–45 Revision 9 System / HW-FW Configuration Menu Figure 7-27. System / HW-FW Configuration
Table of Contents Revision 9 DMD1050 Satellite Modem Board MN-DMD1050 viii F.8.1 Normal QOS ...
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–46 Revision 9 System / Features Menu Figure 7-28. System / Features Menu The Web Browse
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–47 Revision 9 7.3.4.6 Test Menu Test Pattern | Carrier Menu Figure 7-29. Test Pattern
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–48 Revision 9 Pattern Error Count: {NO SYNC, nnnn x 10n} Displays the number of error
MN-DMD1050 A–1 Revision 9 Appendix A. Product Options A.1 Hardware Options The following enhanced interface cards are available. A.2 Internal Hig
DMD1050 Satellite Modem Board Product Options MN-DMD1050 A–2 Revision 9 Notes:
MN-DMD1050 B–1 Revision 9 Appendix B. Carrier Control B.1 States The DMD1050 transmitter will turn off the carrier output automatically when the m
DMD1050 Satellite Modem Board Carrier Control MN-DMD1050 B–2 Revision 9 Modulator output is turned off before reprogramming modulator functions tha
MN-DMD1050 C–1 Revision 9 Appendix C. TCP/IP Ethernet Setup C.1 Introduction The modem supports SNMP, FTP protocols and the Web Browser. Utilizat
DMD1050 Satellite Modem Board TCP/IP Ethernet Setup MN-DMD1050 C–2 Revision 9 Bootp Server (see the next menu selection for setting the BOOTp TAG).
DMD1050 Satellite Modem Board TCP/IP Ethernet Setup MN-DMD1050 C–3 Revision 9 8. MODEM EADDR: This displays the Modem (Unit) Ethernet Address. T
i PREFACE About this Manual This manual describes the installation and operation of the DMD1050. Conventions and References Trademarks Product names
DMD1050 Satellite Modem Board TCP/IP Ethernet Setup MN-DMD1050 C–4 Revision 9 The pinout for this Ethernet Crossover (Null) cable is as follows: R
DMD1050 Satellite Modem Board TCP/IP Ethernet Setup MN-DMD1050 C–5 Revision 9 3. Make sure that the box next to the Internet Protocol (TCP/IP) is
DMD1050 Satellite Modem Board TCP/IP Ethernet Setup MN-DMD1050 C–6 Revision 9 C.5 Testing the Ethernet Connection using the Ping Program (Optional
DMD1050 Satellite Modem Board TCP/IP Ethernet Setup MN-DMD1050 C–7 Revision 9 a. Verify that the correct cables are connected to the Ethernet port
DMD1050 Satellite Modem Board TCP/IP Ethernet Setup MN-DMD1050 C–8 Revision 9 Notes:
MN-DMD1050 D–1 Revision 9 Appendix D. Web Browser Setup Guide D.1 Introduction This section provides quick setup instructions to access the Web B
DMD1050 Satellite Modem Board Web Browser Setup Guide MN-DMD1050 D–2 Revision 9 3. Turn on power to the DMD1050 and allow it to run for 2 minutes.
DMD1050 Satellite Modem Board Web Browser Setup Guide MN-DMD1050 D–3 Revision 9 9. Start the Internet browser on the computer and enter the IP Add
DMD1050 Satellite Modem Board Web Browser Setup Guide MN-DMD1050 D–4 Revision 9 Figure D-4. Password Setup Screen The modem offers addition
DMD1050 Satellite Modem Board Web Browser Setup Guide MN-DMD1050 D–5 Revision 9 Figure D-5. Modem Addressing Screen D.4.2 Configuring the Compu
DMD1050 Revision 9 Preface MN-DMD1050 ii Warranty Policy Comtech EF Data products are warranted against defects in material and workmanship for a pe
DMD1050 Satellite Modem Board Web Browser Setup Guide MN-DMD1050 D–6 Revision 9 D.5 WEB Users Setup and Configurations Controls Options We use aut
DMD1050 Satellite Modem Board Web Browser Setup Guide MN-DMD1050 D–7 Revision 9 Figure 6. User Settings/Access Screen ACCESS rights represent th
DMD1050 Satellite Modem Board Web Browser Setup Guide MN-DMD1050 D–8 Revision 9 D.5.2 Boot Mode Options (Reference only) Boot Modes selections ar
MN-DMD1050 E–1 Revision 9 Appendix E. User Interface Connections E.1 User Interface Connections Supplied mating connectors can be used, but are not
DMD1050 Satellite Modem Board User Interface Connections MN-DMD1050 E–2 Revision 9 Dimensions are in inches Style A B C -07 .100 0.430 0.430
DMD1050 Satellite Modem Board User Interface Connections MN-DMD1050 E–3 Revision 9 J3 & J7 Information on Supplied Interface Connector
DMD1050 Satellite Modem Board User Interface Connections MN-DMD1050 E–4 Revision 9 Part Number: Active08-56-0106 3.96mm (.156") Pitch KK®
MN-DMD1050 F–1 Revision 9 Appendix F. Ethernet Data Interface F.1 Introduction Just like the original Ethernet Bridge, the new Enhanced Ethernet In
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–2 Revision 9 F.2 Point-to-Point Applications Figure F-1 illustrates a typical a
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–3 Revision 9 F.3 The Importance of Transparent Operation In some situations, th
DMD1050 Revision 9 Preface MN-DMD1050 iii Exclusive Remedies Comtech EF Data Corporation’s warranty, as stated is in lieu of all other warranties, e
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–4 Revision 9 F.4 Point-to-Multipoint Applications In many instances, customers
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–5 Revision 9 F.5 High Speed Mesh Applications As shown in Figure F-4, the uniqu
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–6 Revision 9 F.6 Low Speed Mesh Applications For mesh applications with data ra
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–7 Revision 9 F.7 Remote Monitor and Control via SNMP Simple Network Management
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–8 Revision 9 F.8 Enhanced Quality of Service (QOS) Most networks are comprised
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–9 Revision 9 F.8.1 Normal QOS When Normal QOS is selected, the determination of
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–10 Revision 9 F.8.5 Satellite Packet Error Checking Packet error checking is a
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–11 Revision 9 F.8.8 Adding Acceleration, Compression, Network Security, and Tra
DMD1050 Satellite Modem Board Ethernet Data Interface MN-DMD1050 F–12 Revision 9 Notes:
MN-DMD1050 G–1 Revision 9 Appendix G. DMD1050 Strap Codes G.1 Introduction The Strap Code is a quick set key that sets many of the modem parameter
DMD1050 Revision 9 Preface MN-DMD1050 iv Customer Support Support Business Hours - Monday through Friday - 8:00 a.m. to 5:00 p.m. (MST) Comtech EF
DMD1050 Satellite Modem Board DMD1050 Strap Codes MN-DMD1050 G–2 Revision 9 Table G-1. DMD1050 Strap Codes Dis = Disable Strap Code (Decimal) Dat
DMD1050 Satellite Modem Board DMD1050 Strap Codes MN-DMD1050 G–3 Revision 9 Table G-1. DMD1050 Strap Codes Dis = Disable Strap Code (Decimal) Dat
DMD1050 Satellite Modem Board DMD1050 Strap Codes MN-DMD1050 G–4 Revision 9 Table G-1. DMD1050 Strap Codes Dis = Disable Strap Code (Decimal) Dat
MN-DMD1050 H–1 Revision 9 Appendix H. Software Upgrade Procedure H.1 Software Upgrade Procedure The outdoor modem software may be upgraded via the
DMD1050 Satellite Modem Board Software Upgrade Procedure MN-DMD1050 H–2 Revision 9 The value displayed on the top line of this menu is the 12-digi
DMD1050 Satellite Modem Board Software Upgrade Procedure MN-DMD1050 H–3 Revision 9 a. From the main menu, the Features menu. b. “Feature Id
DMD1050 Satellite Modem Board Software Upgrade Procedure MN-DMD1050 H–4 Revision 9 H.7 Web Browser Software Upgrade H.8 Monitor and Control All m
METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX
MN-DMD1050 1–1 Revision 9 Chapter 1. Introduction This chapter provides an overview of the DMD1050 Satellite Board Modem, which is designed for sate
DMD1050 Satellite Modem Board Introduction MN-DMD1050 1–2 Revision 9 The DMD1050's impressive remote accessibility rivals all others in the fi
MN-DMD1050 2–1 Revision 9 Chapter 2. Installation This section provides instructions on unpacking and installation, as well as storage of the unit.
DMD1050 Satellite Modem Board Installation MN-DMD1050 2–2 Revision 9 2.2 Unpacking The DMD1050 Universal Satellite Modem was carefully packaged to
DMD1050 Satellite Modem Board Installation MN-DMD1050 2–3 Revision 9 2.5.1 Standard DMD1050 Factory Configuration Settings Modulator: Data Rat
DMD1050 Satellite Modem Board Installation MN-DMD1050 2–4 Revision 9 2.6 Modulator Checkout The following descriptions assume that the DMD1050 is
DMD1050 Satellite Modem Board Installation MN-DMD1050 2–5 Revision 9 2.6.3 M&C Terminal Setup The initial field checkout of the modem can also
DMD1050 Satellite Modem Board Installation MN-DMD1050 2–6 Revision 9 2.7 Storage It is recommended that the unit be stored in its original sealed
MN-DMD1050 3–1 Revision 9 Chapter 3. Theory of Operation 3.1 DMD1050 Hardware The DMD1050 is based on a two printed circuit card design. The stand
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–2 Revision 9 3.1.1 DMD1050 L-Band Printed Circuit Card The L-Band/IF Printed Circui
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–3 Revision 9 FPGA. There is no limit to the number of digital logic configurations
ER-DMD1050-EA9 Rev - PLM C-0028804 Errata A for MN-DMD1050 Rev 9 Comtech EF Data Documentation Update Subject: Table of Contents and Chapter
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–4 Revision 9 The Baseband Printed Circuit Card also contains the Monitor and Control
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–5 Revision 9 Sync DataI/OCollectorTerrestrial PhyRx DSPTx DSPDigital BasebandProcess
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–6 Revision 9 processes this information and generates status indications as well as
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–7 Revision 9 option is displayed, press the ‘Enter’ key to select that option. The
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–8 Revision 9 1 stop bit 3.3.6 Terminal Screens 3.4 Modem Remote Communications (R
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–9 Revision 9 Connect an Ethernet cable between the unit and a computer that has web
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–10 Revision 9 3.7.1.1 Configuring the Modem to use the Ethernet Data Interface Whe
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–11 Revision 9 The interface sends out another pause frame with the pause time set to
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–12 Revision 9 3.7.1.8 Setting Up The DMD1050 Ethernet Bridge To Operate Like A FIF
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–13 Revision 9 3.7.1.9 Packet Statistics The following statistics are available und
Table of Contents Revision 9 DMD1050 Satellite Modem Board MN-DMD1050 v CHAPTER 4. REAR PANEL INTERFACE ...
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–14 Revision 9 3.9 Loopback Features (Terrestrial & IF) The modem provides for a
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–15 Revision 9 Figure 3-6. Loopback Functional Block Diagram
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–16 Revision 9 Figure 3-7. Loopback Functional Block Diagram Figure 3-8. Loopba
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–17 Revision 9 3.10 DMD1050 Clocking Options The DMD1050 supports a number of differ
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–18 Revision 9 The following paragraphs define the types of clocking options availabl
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–19 Revision 9 3.10.2 RX Buffer Clock Options The DMD1050 supports a number of RX Bu
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–20 Revision 9 3.11 Ethernet Data Interface The modem supports dual port 10/100 Bas
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–21 Revision 9 3.12.3 Interleaving The DMD1050 allows for interleaving depths of 4 or
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–22 Revision 9 3.13 DMD1050 Automatic Uplink Power Control (AUPC Operation) The mode
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–23 Revision 9 3.13.2 EF AUPC In this case, Target Eb/No indicates the local unit wa
MN-DMD1050 6–1 Revision 9 Chapter 6. Technical Specifications 6.1 Data Rates BPSK Uncoded 4.8 Kbps to 10.0 Mbps 1/2 Rate BPSK 2.4 Kbps to 5.0 Mbp
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–24 Revision 9 Table 3-2. Local AUPC Functions Function AUPC Available Options De
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–25 Revision 9 3.14 Asynchronous Overhead Operation (J1) This port is also dedicate
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–26 Revision 9 Table 3-4. Pin Assignments Kbps Baud Rate Example for Standard IBS Kb
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–27 Revision 9 3.15 Standard IBS ES to ES Mode In the first or “Normal” mode, all bi
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–28 Revision 9 3.16 Enhanced Asynchronous Mode (Radyne Proprietary) Since many of t
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–29 Revision 9 3.17.1 SCC Framing Structure Each SCC frame consists of the following:
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–30 Revision 9 3.17.2 Aggregate Data Rate The aggregate data rate equals the followin
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–31 Revision 9 3.17.3 Overhead Rate Comparison The SCC Overhead Ratio varies depend
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–32 Revision 9 3.17.4 Actual Overhead Rate Calculation The following is the actual c
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–33 Revision 9 3.17.5 SCC Overhead Channel Setup 1. Set the Framing Mode (located
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–3 Revision 9 6.9 Data Rate Limits 6.9.1 Non-DVB Modulation Code Rate Min D
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–34 Revision 9 SCC Overhead Chart Examples (Viterbi 3/4 w/V.35 Scrambler) Modem Data
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–35 Revision 9 3.18 DMD1050 ID Codes (Feature Upgrades) The modem has unique ID code
DMD1050 Satellite Modem Board Theory of Operation MN-DMD1050 3–36 Revision 9 Notes:
MN-DMD1050 4–1 Revision 9 Chapter 4. Rear Panel Interface This section discusses the electrical interfaces available from the rear panel. All locat
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–2 Revision 9 Figure 4-1. DMD1050 Front View Figure 4-2. DMD10
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–3 Revision 9 Figure 4-3. DMD1050 Top View SMA OPT (F) TX L-BAND SMA OPT
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–4 Revision 9 Figure 4-4. DMD1050 Bottom View J1 ASYNC & RLLP J2 DATA I
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–5 Revision 9 4.2 Compact Flash (J9) The compact flash slot is located on the right
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–6 Revision 9 4.4.4 ASYNC & Remote Port (J1) - 10 Pin Dual Row Header This port
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–7 Revision 9 4.4.4.1 Default/Shorting Plug (JP5 JP6) - 3 Pin Male Connector If us
Copyright © 2011 Comtech EF Data. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–8 Revision 9 4.4.5 TERMINAL - Factory use only 4.4.6 MIL-188-114A (J2) EIA-530 P
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–9 Revision 9 4.4.7 ETHERNET M&C (J10) The Ethernet M&C Port is a 10 Base-T
DMD1050 Satellite Modem Board Rear Panel Interface MN-DMD1050 4–10 Revision 9 Notes:
MN-DMD1050 5–1 Revision 9 Chapter 5. Maintenance and Troubleshooting 5.1 Periodic Maintenance The DMD1050 does not require periodic maintenance. 5
DMD1050 Satellite Modem Board Maintenance and Troubleshooting MN-DMD1050 5–2 Revision 9 5.2.1 Alarm Faults 5.2.1.1 Major Tx Alarms Alarm Possib
DMD1050 Satellite Modem Board Maintenance and Troubleshooting MN-DMD1050 5–3 Revision 9 5.2.1.4 Minor Rx Alarms Alarm Possible Cause BUFF UNDERF
DMD1050 Satellite Modem Board Maintenance and Troubleshooting MN-DMD1050 5–4 Revision 9 Active Alarms Common Equipment Alarms A feature exis
MN-DMD1050 6–1 Revision 9 Chapter 6. Technical Specifications 6.1 Data Rates BPSK Uncoded 4.8 Kbps to 10.0 Mbps 1/2 Rate BPSK 2.4 Kbps to 10.0 Mb
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–2 Revision 9 Internal Stability +/- 1 x 10-6 High Stability (optional) +/- 5
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–3 Revision 9 6.9 DMD2050 Data Rate Limits 6.9.1 Non-DVB Modulation Code Rat
This page is intentionally blank.
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–4 Revision 9 OQPSK SEQ 7/8 8400 2048000 OQPSK TPC 1/2 4582 9545454 OQPSK
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–5 Revision 9 188 Mode Modulation Code Rate Min Data Rate Max Data Rate BPSK
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–6 Revision 9 6.10 DMD1050 BER Specifications 6.10.1 BER Performance (Viterbi)
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–7 Revision 9 6.10.2 BER Performance (Sequential) 1E-9 1E-8 1E-7 1E-6 1E-5 1E-4
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–8 Revision 9 6.10.3 BER Performance (Viterbi with Reed-Solomon) 1E-9 1E-8 1E-7
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–9 Revision 9 6.10.4 BER Performance (8PSK Trellis) 1E-9 1E-8 1E-7 1E-6 1E-5 1
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–10 Revision 9 6.10.5 BER Performance (16QAM Viterbi) 1E-9 1E-8 1E-7 1E-6 1E-5
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–11 Revision 9 6.10.6 BER Performance (16QAM Viterbi with Reed-Solomon) 1E-9 1E
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–12 Revision 9 6.10.7 BER Performance ((O)QPSK Turbo) 1E-9 1E-8 1E-7 1E-6 1E-5
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–13 Revision 9 6.10.8 BER Performance (8PSK Turbo) 1E-9 1E-8 1E-7 1E-6 1E-5 1
iii Table of Contents CHAPTER 1. INTRODUCTION ... 1–
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–14 Revision 9 6.10.9 BER Performance (16QAM Turbo) 1E-9 1E-8 1E-7 1E-6 1E-5 1
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–15 Revision 9 1/2 Rate 3/4 Rate 7/8 Rate 1/2 Rate 3/4 Rate 7/8
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–16 Revision 9 3/4 Rate 7/8 Rate 3/4 Rate 7/8 Rate 1E-3 8.4 dB
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–17 Revision 9 Table 6-10. IBS/IDR Compliant Framing Modes BER Specifica
DMD1050 Satellite Modem Board Technical Specifications MN-DMD1050 6–18 Revision 9 6.10.11 ACG Output Voltage The AGC Output Voltage is a function
MN-DMD1050 7–1 Revision 9 Chapter 7. Web Browser 7.1 Web Browser User Interface The Web Browser interface for DMD1050 can be accessed through the R
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–2 Revision 9 7.2.1 Appearance This site is a monitor and control of an individual complete
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–3 Revision 9 7.2.3 LED Indicators Twelve LEDs on the DMD1050 GUI Interface (Refer to Table
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–4 Revision 9 7.3 GUI Screen Menus There are four main menus displayed on the Introduction
DMD1050 Satellite Modem Board Web Browser MN-DMD1050 7–5 Revision 9 7.3.1 Introduction Menu This menu will first appear when starting up the web b