Comtech EF Data MBT-4000B Spezifikationen Seite 72

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 88
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 71
MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–20
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Maintenance
Status
N/A
All
103 bytes (MBT),
98 bytes (BDC),
98 bytes (BUC),
alphanumeric
Query only.
Used to Query the maintenance status of the unit.
Example for MBT-4000B base:
>0001/RMS={cr}{lf}
15VT1=015.1{cr}
7V5T1=007.7{cr}
5VLT1=005.0{cr}
28VT1=027.2{cr}
REFVT=001.3{cr}
LNA_1=000.0{cr}
LNA_2=000.0{cr}
RFSWP=B{cr}
IFSWP=N{cr}
RRFSW=B{cr}
RIFSW=B{cr}{lf}
Example for BUC: <0001A2/RMS={cr}
>0001A2/RMS={cr}{lf}
15VT=015.1{cr}
7V5T=007.6{cr}
5VLT=005.2{cr}
REFV=XXX.X{cr} (reserved for future use)
SYNT=007.2{cr}
POUT=XXX.X{cr} (reserved for future use)
TEMP=+25.0{cr}{lf}
Example for BDC: <0001A1/RMS={cr}
>0001A1/RMS={cr}{lf}
15VT=015.1{cr}
7V5T=007.6{cr}
5VLT=005.2{cr}
REFV=XXX.X{cr} (reserved for future use)
SYNT=007.2{cr}
LNAC=255.0{cr}
TEMP=+25.0{cr}{lf}
Note: “REFV” will show tuning voltage of reference OSC for standalone.
Otherwise REFV=xxx.x which means Not Applicable.
N/A
RMS?
RMS=x….x
(see Description of
Arguments for
details)
Seitenansicht 71