CLO-10 Link Optimizer Installation and Operation Manual For Firmware Version 1.2.1 or higher (see New in this Release - Section 1.7)
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A–12 A.5 Cables and Connections Once the CLO-10s and the accompanying equi
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM ► To replace a faulted Traffic Unit that is being backed up by the Redunda
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.6 Front Panel Operation Configuration and operation of the CLO-10 in re
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.6.2 Traffic Unit Redundancy Configuration Each Traffic Unit must have i
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.6.3.1 Redundancy Enable /Disable If En/Dis is selected: Redundancy En
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.6.3.4 Establish the Operating Mode When adding or removing a CLO-10 in
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM • On Traffic Unit #2: o The green ONLINE LED flashes to indicate if that
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM Figure A-14 illustrates the operational status of the front panel LEDs for
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM From the Remote Control submenu, select Serial using the ◄ ► arrow keys,
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.6.4 Set Operation Mode The CLO-10 is shipped in the AUTO-OFF (manual op
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM There will be no switchover if the Redundant Unit is faulted. Ensure that
CLO-10 Link Optimizer Installation and Operation Manual For Firmware Version 1.2.1 or higher (see New in this Release - Section 1
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A–26 A.7 Daisy Chain Remote Addressing This appendix provides details of
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM Figure A-17. CLO-10 Daisy Chain Addressi
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM Figure A-19. CLO-10 Base Addressing Sc
Appendix B. REMOTE CONTROL B.1 Overview This section describes the protocol and message command set for remote monitor and control of the CLO-10 Lin
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM RS-485 (full duplex) summary: Two differential pairs - one pair for Controller-to-ta
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM Target-to-controller: Start of Packet Target Address Address De-limiter Instruction
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B.5.4 Instruction Code Qualifier This single character further qualifies the precedi
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM # (ASCII code 35) The # code (Target to Controller) is only used as follows: If the
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-6 B.6 Remote Commands and Queries This section organizes the remote command and qu
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B.6.1 Switch Remote Commands and Queries for the CLO-10 Link Optimizer Par
This page is intentionally blank.
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-8 Parameter Type Command (Instruction Code and Qualifier) Arguments for Co
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B.6.2 Remote Commands and Queries For the CLO-10 Link Optimizer Parameter
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-10 Parameter Type Command (Instruction Code and Qualifier) Arguments for C
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-11 Parameter Type Command (Instruction Code and Qualifier) Arguments for
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-12 Parameter Type Command (Instruction Code and Qualifier) Arguments for C
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-13 Parameter Type Command (Instruction Code and Qualifier) Arguments for
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-14 Parameter Type Command (Instruction Code and Qualifier) Arguments for C
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B.6.3 Commands and Queries Parameter Type Command (Instruction Code and qu
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-16 Parameter Type Command (Instruction Code and qualifier) Arguments for C
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-17 Parameter Type Command (Instruction Code and qualifier) Arguments for
CLO-10 Link Optimizer Revision 1 Table of Contents MN/CLO-10.IOM Table of Contents TABLE OF CONTENTS ...
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-18 Parameter Type Command (Instruction Code and qualifier) Arguments for C
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-19 Parameter Type Command (Instruction Code and qualifier) Arguments for
CLO-10 Link Optimizer Revision 1 Remote Control MN/CLO-10.IOM B-20 Notes:
METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281 0.01
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX
CLO-10 Link Optimizer Revision 1 Table of Contents MN/CLO-10.IOM 1.3 Description of CLO-10 Features...
CLO-10 Link Optimizer Revision 1 Table of Contents MN/CLO-10.IOM 3.8 DC Power Connector ...
CLO-10 Link Optimizer Revision 1 Table of Contents MN/CLO-10.IOM CONFIG: Remote Æ Ethernet Æ Gateway ...
CLO-10 Link Optimizer Revision 1 Table of Contents MN/CLO-10.IOM 6.8 SAVE/LOAD ...
CLO-10 Link Optimizer Revision 1 Table of Contents MN/CLO-10.IOM A.6.3.5 Set the Redundant Unit Address via the Main Menu ...
CLO-10 Link Optimizer Revision 1 Table of Contents MN/CLO-10.IOM Figures Figure 1-1. CLO-10 Link Optimizer ...
CLO-10 Link Optimizer Revision 1 Table of Contents MN/CLO-10.IOM x This page is intentionally blank.
Preface Customer Support Contact the Comtech EF Data Customer Support Department for: • Product support or training • Reporting comments or sugges
CLO-10 Link Optimizer Revision 1 Preface MN/CLO-10.IOM xii About this Manual This manual provides installation and operation information for the Com
CLO-10 Link Optimizer Revision 1 Preface MN/CLO-10.IOM Trademarks Product names mentioned in this manual may be trademarks or registered trademarks
CLO-10 Link Optimizer Revision 1 Preface MN/CLO-10.IOM Safety Compliance EN 60950 Applicable testing is routinely performed as a condition of manufa
CLO-10 Link Optimizer Revision 1 Preface MN/CLO-10.IOM Warranty Policy Comtech EF Data products are warranted against defects in material and workma
CLO-10 Link Optimizer Revision 1 Preface MN/CLO-10.IOM xvi A fixed charge established for each product will be imposed for all equipment returned fo
1–1 Chapter 1. INTRODUCTION 1.1 Overview The CLO-10 is Comtech EF Data’s Link Optimizer incorporating DoubleTalk™ Carrier-in-Carrier® technology. The
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM 1.2 Features The CLO-10 includes the following features: • DoubleTalk™ Carrier-in-Carr
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM 1.2.4 Remote Control The operator may configure and monitor the modem from the front pa
AGILE DOC ID ER-MN-CLO- 10_EA1 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! AGILE CO4012 1 Errata A Comtech EF Data Documentation Update Sub
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM 1.5 FAST Options and Hardware Options The CLO-10 incorporates several optional features
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM 1.5.2 Hardware Options Redundancy is the only available hardware option for the CLO-10.
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM CDM-600 Satellite ModemUpconverter DownconverterCDM-600 Satellite ModemUpconverter Down
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM Because acquiring the delay and frequency offset of the interfering carrier is fundament
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM 1.6.3 System Functionality Carrier-in-Carrier® achieves its cancellation performance du
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM modem and the CLO-10 itself. The CLO-10 tracks and compensates for this frequency offset
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM 1.8 Summary of Specifications 1.8.1 System Specifications Characteristic Requirement
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM 1.8.2 Environmental and Physical Specifications Characteristic Requirement Operating T
CLO-10 Link Optimizer Revision 1 Introduction MN/CLO-10.IOM 1–12 1.9 Dimensional Envelope Figure 1-7 shows the dimensional envelope for the CLO-10
Chapter 2. INSTALLATION 2.1 Unpacking and Inspection The CLO-10 Link Optimizer and its Installation and Operation Manual are packaged and shipped in
AGILE DOC ID ER-MN-CLO- 10_EA1 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! AGILE CO4012 2
CLO-10 Link Optimizer Revision 1 Installation MN/CLO-10.IOM 2.2 Mounting Figure 2-1 provides a “cut-away” side view of a typical CLO-10 rack config
CLO-10 Link Optimizer Revision 1 Installation MN/CLO-10.IOM Figure 2-1. Typical CLO-10 Rack Installation (Side View) 2–3
CLO-10 Link Optimizer Revision 1 Installation MN/CLO-10.IOM 2–4 Equipment Rack Rear Mounting Rail #10 Shoulder Screw #10 Bracket Bolt Support Brac
Chapter 3. REAR PANEL CONNECTORS 3.1 Connector Overview The connectors located on the CLO-10 rear panel (Figure 3-1) provide all necessary external
CLO-10 Link Optimizer Revision 1 Rear Panel Connectors MN/CLO-10.IOM 3.2 External Reference Connector, J1 (BNC-F) The J1 External Reference Input i
CLO-10 Link Optimizer Revision 1 Rear Panel Connectors MN/CLO-10.IOM 3.5 M&C 10/100 BaseT Ethernet Management Port (RJ-45) This is a standard R
CLO-10 Link Optimizer Revision 1 Rear Panel Connectors MN/CLO-10.IOM 3.6 IOM/IOSM Connectors (BNC-F) The CLO-10 may be used in Standalone config
CLO-10 Link Optimizer Revision 1 Rear Panel Connectors MN/CLO-10.IOM 3–5 3.7 IEC Line Input (AC Power) Connector The IEC line input connector conta
CLO-10 Link Optimizer Revision 1 Rear Panel Connectors MN/CLO-10.IOM 3–6 3.9 Ground Connector A #10-32 stud is used for connecting a common chassis
4–1 Chapter 4. CABLES AND CONNECTIONS 4.1 Overview IMPORTANT Leave the CLO-10, up and down converters, and modem powered OFF until all conn
AGILE DOC ID ER-MN-CLO- 10_EA1 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! AGILE CO4012 3
CLO-10 Link Optimizer Revision 1 Cables and Connections MN/CLO-10.IOM 4–2 Figure 4-1. CLO-10 External Cable C
5–1 Chapter 5. MODEM AND OPTIMIZER CONFIGURATION 5.1 Modem Configuration Tune the modem to the desired operating frequency within the 50-90 MHz or 10
CLO-10 Link Optimizer Revision 1 Modem and Optimizer Configuration MN/CLO-10.IOM 5.2.2 Flash Updating The CLO-10 eliminates the need for updating fi
CLO-10 Link Optimizer Revision 1 Modem and Optimizer Configuration MN/CLO-10.IOM 5.2.3 CLO-10 FTP Upload Procedure 1. Identify the reflashable prod
CLO-10 Link Optimizer Revision 1 Modem and Optimizer Configuration MN/CLO-10.IOM For additional help with "zipped" file types, refer to &qu
CLO-10 Link Optimizer Revision 1 Modem and Optimizer Configuration MN/CLO-10.IOM b. Terminate the FTP session by typing "bye" and closing
CLO-10 Link Optimizer Revision 1 Modem and Optimizer Configuration MN/CLO-10.IOM 5–6 5.2.4.2 Link Access Setup For establishing a link when using C
Chapter 6. FRONT PANEL OPERATION 6.1 Introduction LED Vacuum Fluorescent Indic
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.1.1 LED Indicators The eight LEDs positioned to the left side of the front
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.1.2 Keypad The keypad on the front panel contains six individual key switc
AGILE DOC ID ER-MN-CLO- 10_EA1 THIS DOCUMENT IS NOT SUBJECT TO REVISION/UPDATE! AGILE CO4012 4 This page is intention
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.1.3 Vacuum Fluorescent Display (VFD) This ‘welcome screen’ is displayed wh
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.2 CLO-10 Menu Structure Figure 6-2 shows the menu structure of the CLO-10. T
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.3 Main (Top-level Select) Menu MAIN MENU: Config Mon Test Info Save
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.4 CONFIG (Configuration) CONFIG: Remote BW Uplink Downlink Remod Cn
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.4.1 CONFIG: Remote Remote Control: Local Serial Ethernet (◄ ► ENT)
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM CONFIG: Remote Æ Serial Æ Baudrate If Baudrate is selected: Local M&am
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM M&C Port MAC Address: 00-06-B0-00-00-D5 6.4.2 CONFIG: BW (Bandwidth)
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.4.5 CONFIG: Remod (Remodulation Parameters) Remod: Frequency On/Off
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.4.6 CONFIG: CnC (Carrier-in-Carrier© Parameters) CnC: SearchDelay Freq
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM CONFIG: Misc: Æ Alarm Mask: Æ Unit Unit Alarm Mask: ◄ ► ERC ACQ_FAI
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A–9 Figure A-8 shows the functional block diagram of Bridge Mode. In this
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM CONFIG: Misc: Æ Reference (Reference Oscillator) The CLO-10 can accept an exter
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.5 Monitor Monitor: Alarms Event Log CnC Temp RSL (◄ ► ENT) Selec
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM • CnC lock (Loss of lock) • Ext Ref Clock (External Reference Clock) • SW Co
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM Monitor: Alarms Æ( Live Alarms:) Remod (Remod Alarms) If Remod is selected:
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM If Clear-All is selected, the user is prompted to confirm that all events will
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.6 TEST TEST: Mode LampTest (◄ ► ENT) Select Mode or
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.7 INFO (Information) INFO: Remote Bw Uplink Downlink Remod CnC Ref
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM INFO: Downlink (Downlink Information) Select INFO: Downlink to display the unit
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.8 SAVE/LOAD Save/Load Configuration: Save Load (◄ ► ENT) These
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM Save/Load: Load (Load Configuration) If Load is selected and there is a configu
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A–10 Figure A-8. CLO-10 Daisy Chain Redundancy – Bridge Mode
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6.9 UTILITY UTILITY: Clock Ref ID Display Firmware FAST ◄ ► Press ENTE
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM Utility: ID (Circuit Identification) Edit Circuit ID:(◄ ► ▲ ▼ ENT) 28 CHARAC
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM If Information is selected: Firmware Info: Bootrom Image#1 Image#2 (◄ ►
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM Utility: FAST (FAST Code Options) FAST: Config View Board S/N: 123456789
CLO-10 Link Optimizer Revision 1 Front Panel Operation MN/CLO-10.IOM 6–28 Notes:
Appendix A. REDUNDANT SYSTEM OPERATION A.1 Introduction The Comtech EF Data CLO-10 Link Optimizer, when operating with Firmware Version 1.2.1 or lat
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM Figure A-1. CLO-10 1:1 Daisy Chain Redundancy Figure A-2. CLO-10 1:N Dai
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.1.2 Redundancy System Operational Rules For proper operation of the CLO
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.2 Installation For information pertaining to the CLO-10’s unpacking, in
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.3 Description of Modules The CLO-10 can be equipped with one of two pos
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A–11 Figure A-9. CLO-10 Daisy Chain Configuration – Backup Mode
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.3.1.2 Overview: CLO-10 With Input/Output Switch Module (IOSM) The CLO-
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.3.2.2 IOM / IOSM BNC Connectors Table A-1. IOM (CEFD P/N PL/12833
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.4 Description of Operation Ease of Connection: Because the redundancy s
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM Figure A-8 shows the functional block diagram of Bridge Mode. In this exam
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM Figure A-8. CLO-10 Daisy Chain Redundancy – Bridge Mode A–10
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM Figure A-9. CLO-10 Daisy Chain Configuration – Backup Mode A–11
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.5 Cables and Connections Once the CLO-10s and the accompanying equipmen
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.5.2 1:1 Redundancy Configuration Cabling Figure A-10. CLO-10 1:1 Daisy
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.5.3 1:N Redundancy Configuration Cabling
CLO-10 Link Optimizer Revision 1 Redundant System Operation MN/CLO-10.IOM A.5.4 Adding and Removing CLO-10s and/or Modules ► To add an additional C